The bed design with flat pallet of the GEMINI TF Big Bore PET/CT system meets the AAPM TG-66 positioning accuracy requirements for radiation treatment planning. Setapp crack mac. The 53cm flat pallet accommodates immobilization accessories to facilitate consistent patient positioning between treatment planning and treatment delivery. T he Gemini TF PET/CT (Philips Medical Systems) is a new high-performance, time-of-flight (TOF) capable, fully 3-dimensional (3D) PET scanner together with a 16-slice Brilliance CT scanner.
-
|
Philips Gemini Tf Operator Manual Free
Philips Gemini Tf Operator Manual Download
- GEMINI TF, 16-channel configuration system puts you ahead of the applications curve. In addition to providing additional confidence during routine oncology FDG studies, the acquisition speed of PET and CT enables you to perform advanced applications such as pulmonary gating, cardiac studies and molecular imaging.
- Advanced Mobility, headquartered in Chicago, Illinois, is a leading, world-class manufacturing company focused on designing and building custom trailers.
Philips Gemini Tf Operator Manual Online
| |||||||||||||||||||||||||||
Philips Healthcare proposed corrective action plan (CAP) is comprised of the following elements: * Updating procedures in manufacturing to verify, either through software calibration or through gage-pin measurement, that A-plane collimation is appropriate to the design specification. It is our understanding that these procedures have been implemented. * For refurbished PET/CT and SPECT/CT systems distributed by Philips, the manufacturing process now requires that CTDI testing be conducted in addition to air testing and that each system meet updated CTDI tolerance limits to be published in the product's instructions for use. * Reassessing and correcting the correlation between air dose and CTDI specifications for all CT systems or sub-systems, resulting in updates of the CTDI specifications (tolerances) to be published in the instructions for use. It is our understanding that this reassessment and correction have been implemented, that the updated CTDI specifications will be made available as new CTDI tolerance tables with the customer information letter to be distributed immediately, and that these updated CTDI specifications will also be distributed as an addendum to the instructions for use manuals to the installed base during the next 12 months. * For all Brilliance CT, Gemini PET/CT, and Precedence SPECT/CT systems, in the installed base as well as in forward production, instructions for field service will be updated to provide clear directions on how to verify that the A-plane collimator has been appropriately adjusted to ensure expected product performance after its replacement and/or the replacement of an x-ray tube. This plan appears to adequately address the problem, and it is hereby approved. For further questions please call (978) 687-1501. | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2089 US 4036 ROW | |||||||||||||||||||||||||||
Worldwide Distribution including USA (nationwide) | |||||||||||||||||||||||||||
TPLC Device Report | |||||||||||||||||||||||||||
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 The manufacturer has initiated the recall and not all products have been corrected or removed. This record will be updated as the status changes. |